- ← Back to Support
EZCODE / SUPPORT
TBH-BLE
Wireless barcode scanner
Setup guideUSB · 2.4G · Bluetooth HID / BLE
SPP is not supported on this model.
Scan only the setting you need. Use your scanner, not your phone camera.
Save to your phone: open a group image, then touch and hold to save it. Enlarge before scanning, or print the saved image.Basic settings
Use reset only if needed. It removes custom settings.
Open / save basic settings image ↗Factory reset

Restores initialization settings. Reconnect the scanner afterwards.
Version information

Read the device version for technical support.
Battery level

Read the remaining battery power.
Scan mode
Choose ONE scanning mode.
Open / save scan mode image ↗Manual trigger

Press the scanner button to scan.
Continuous scanning

Keep scanning continuously without pressing the trigger for each scan.
Auto-sensing

Scan automatically when a barcode is presented.
Barcode types
Each setting controls one barcode family. Choose only the setting you need.
2D is not QR-only. Enable 2D allows the supported 2D formats, not just QR codes. Avoid disabling both barcode families.
Open / save barcode types image ↗Enable 1D

Allow supported 1D barcode types.
Disable 1D

Stop reading 1D barcodes.
Enable 2D

Allow supported 2D barcode types.
Disable 2D

Stop reading 2D barcodes.
Bluetooth pairing
Scan Step 1, then Step 2. Finish in your device settings.
After Step 1 and Step 2, open Bluetooth settings and select Barcode Scanner HID. A beep confirms the connection. You can also hold the trigger for 10 seconds to enter pairing mode. BLE is a separate mode, not a third pairing step. This scanner has no SPP mode.
Open / save bluetooth pairing image ↗Step 1 - HID mode

Standard Bluetooth keyboard input.
Step 2 - Pairing

Then select Barcode Scanner HID on your device.
2.4G receiver
The original receiver is paired at the factory.
Plug the original USB receiver into your host. Re-pair only if the connection is not working: scan Step 1, then Step 2. The green indicator flashes during pairing; steady blue indicates a completed pairing.
Open / save 2.4g receiver image ↗Step 1 - 2.4G mode

Plug the USB receiver into your host. Use if reconnection is needed.
Step 2 - Re-pair

Match Enforced: use if data still does not reach the host.
BLE & Virtual COM
Alternatives for compatible software. This model does not support SPP.
Open / save ble & virtual com image ↗Virtual COM

Plug in the 2.4G receiver, then scan. Use the supplier driver if needed.
Bluetooth BLE

Use only with a compatible Bluetooth Low Energy application.
iOS keyboard
On-screen keyboard controls for Bluetooth HID.
Open / save ios keyboard image ↗Show / hide keyboard

Scan this code to toggle the iOS keyboard.
Double-click: on

Enable the double-click keyboard shortcut.
Double-click: off

Disable the double-click keyboard shortcut.
Beep volume
Choose ONE volume setting.
Open / save beep volume image ↗Transfer speed
Choose ONE output speed for your host.
Open / save transfer speed image ↗Data & inventory
Upload and verify stored scans before clearing data.
Open / save data & inventory image ↗Normal mode

Send scans to the connected host in real time.
Inventory mode

Store scanned data in the scanner.
Upload stored data

Transfer saved scans to the connected host.
Count stored scans

Display the stored barcode quantity.
Clear stored data

DELETES saved scans. Upload and verify first.
Sleep & power
Choose ONE sleep time. Power off is a separate action.
Open / save sleep & power image ↗1 minute

Sleep after 1 minute of inactivity.
5 minutes

Sleep after 5 minutes of inactivity.
10 minutes

Sleep after 10 minutes of inactivity.
30 minutes

Sleep after 30 minutes of inactivity.
Never sleep

Disable automatic sleep.
Power off now

Switch the scanner off immediately.
End-of-scan character
Choose ONE ending character for your application.
Open / save end-of-scan character image ↗CR

Carriage return.
LF

Line feed.
CR + LF

Carriage return and line feed.
Tab

Tab after each scan.
No suffix

No ending character.
Keyboard language
Match the scanner to the host keyboard layout.
Open / save keyboard language image ↗English

English keyboard layout.
German

German keyboard layout.
Spanish (Spain)

Spanish keyboard layout.
Portuguese

Portuguese keyboard layout.
Portuguese (Brazil)

Brazilian Portuguese keyboard layout.
Turkish Q

Turkish Q keyboard layout.
Turkish F

Turkish F keyboard layout.
International

Windows only. Use if a language mismatch causes garbled text.
Reverse-image barcodes
Choose ONE option for white codes on a black background.
Open / save reverse-image barcodes image ↗Allow

Allow reading white barcodes on a black background.
Forbid

Disable reading white barcodes on a black background.
Advanced data formatting
Configure a prefix or suffix first, then scan the required characters in order. Do not scan the character tables as ordinary setup codes.
Add a prefix / suffix
Scan ONE setup code, then characters from the appendix.
Open / save add a prefix / suffix image ↗Set to add prefix

Then scan the desired characters in order. Maximum 32 bytes.
Set to add suffix

Then scan the desired characters in order. Maximum 32 bytes.
Hide leading / trailing data
Scan ONE setup code, then choose ONE length (1-4 bytes).
Open / save hide leading / trailing data image ↗Step 1 - Hide prefix

Hide characters at the beginning of the barcode.
Step 1 - Hide suffix

Hide characters at the end of the barcode.
Step 2 - 1 byte

Choose one length after the setup code.
Step 2 - 2 bytes

Choose one length after the setup code.
Step 2 - 3 bytes

Choose one length after the setup code.
Step 2 - 4 bytes

Choose one length after the setup code.
Character table - 1 · 24 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 1 image ↗Character table - 2 · 24 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 2 image ↗Character table - 3 · 24 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 3 image ↗Character table - 4 · 24 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 4 image ↗Character table - 5 · 24 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 5 image ↗Character table - 6 · 7 codes
Advanced: scan only after Add prefix / suffix setup.
Open / save character table - 6 image ↗ ← Back to SupportConnection tips
Connected but no data? Check the blue indicator. Inventory mode stores scans; upload stored data, or choose Normal mode for real-time output.
Moving to another device? This scanner connects to one device at a time. Remove the previous pairing and follow the Bluetooth setup steps.
Garbled characters? Match the keyboard language to your host. International keyboard mode is for Windows only.
USB cable: connecting to the host switches to wired mode and charging. Unplugging returns to wireless mode; re-pair if it does not reconnect.